RG-58 is often referred to as Thinnet.
10Base2, 10Mbps, 185 meters per segment, 50-ohm resistance.
Connectors may be BNC, 'T' connectors, and barrel connectors.
The 5-4-3 rule is applied as follows:
There are 5 segments with 4 repeaters and 3 segments may be populated.
A segment may constitute 30 nodes with a repeater counting as a node.
With either Thicknet or Thinnet a ground is required at only one end of a segment.
| Ethernet | Cable | Max distance | Max speed | Connector | |
|---|---|---|---|---|---|
| 10Base5 | Coax | 500 meters | 10Mbps | Vampire Tap, AUI, DB-15 | |
| 10Base2 | Coax | 185 meters | 10Mbps | BNC, 'T', barrel | |
| 10BaseT | CAT 3, 4, 5 | 100 meters | 10Mbps | RJ-45 |
| Ethernet | Cable | Max distance | Max speed | Connector | Notes |
|---|---|---|---|---|---|
| 100BaseTX | CAT 5 | 100 meters | 100Mbps | RJ-45 | Uses 2 pair |
| 100BaseT4 | CAT 3, 4, 5 | 100 meters | 100Mbps | RJ-45 | No full duplex |
| 100BaseVG | CAT 3, 4, 5 | 100 meters | 100Mbps | RJ-45 | VGAnyLAN |
| Ethernet | Cable | Max distance | Max speed | Connector |
|---|---|---|---|---|
| 1000BaseCX | STP | 25 meters | 1000Mbps | DB-9 |
Hardware devices at the Network layer, Data link layer and the Physical layer.